Greetings,Gabriel!
I understand that you had
1) Set the Order Type that you use for Maintenance Items to "Released Immediately" in Order Type config
and at the same time you've
2) Set the field CAUFVD-ANZLU to "Required" in the Field Selection for PM Order Header
Hence you get the error
Field 'Syst.Condition' must still be filled
Message no. IW464
Diagnosis
The field &1 has been defined as a required entry field in your company, but is still empty.
Procedure
Enter the required data in the field &1.
I feel that the solution to your problem is to specify the System Condition explicilty on the Maitnenance Item level. It will transfer to the Order created and hence allow the release. See the screenshot and the thread below (as mentioned by
)